[Error Message]
Qualys Guard detects a potential security vulnerability and report a message as follows .
QID: 42435 detected on port 5555 over TCP
HP Data Protector A.08.10: INET, internal build 205, built on Sat 27 Sep 2014 12:16:29 PM JST
[Cause]
It has already been reported as CVE-2014-2623 (SSRT101644) .
[Workaround / Fix]
Please consider to enable Encrypted Control Communications (ECC) services on the cell server and all of the clients in cell.
Even if ECC is enabled , Qualys Guard will keep reporting that message
because Qualys Guard will not check about ECC settings .
Please contact Qualys Guard support to confirm if the message can be stopped .