Hi,
I'm trying to perform a replication of a previous backup session that completed to a StoreOnce 4700 but want to use a different source device. I need to script this so am using the omniobjcopy command.
The command syntax I'm using is:
omniobjcopy -replication -session 2016/11/10-44 -sourcedevice "NewSourceDev" -targetdevice "TargetDev"
The problem is that no matter what I define the source device to be, it defaults back to the original device that was used for the backup. Unfortunately, the original device is behind a firewall and can't communicate with the target device. This results in the error:
[Critical] From: CMA-NET@OriginalServer "OrigBackupDev [GW 3340:1:6224988868828998542]" Time: 10/11/2016 14:49:17
[90:205] Cannot connect to Media Agent (IPC Invalid Hostname or IP Address
System error: [11004] No data record available
) => aborting
However, when I define the object copy (replication) in the GUI it works fine.
Does this happen to anyone else?
DP details:
v9.06 Build 107
StoreOnce 4700 Catalyst Store
Cell Manager on Windows 2012R2
Many thanks,
John