Hi,

I've recently installed data protector 9.07 {included recent released patches] and setup backup host[Vepa agent] on 2 physical servers with Store CoFC.

I've seen strange data flow behaviour between [Datastore =<=FC>=>IP=> Storeonce CoFC, might due to configuration error by me :P.

I've installed 2 backup host {physical servers] with VEPA agents and also configured both backup hosts GATEWAY [FC] in Cell manager GUI.

 

configuration:

2 physical backup hosts {BKHost-A, BKHost-B configured with VEPA {+ configured as FC GATEWAY {CoFC} - in GUI }

+ datastore lun's are presented to both BK hosts.

my question is:

Can i have more than 1 VEPA agents in my environment ? if yes - how i can use them ? by adding gateway or by adding some configuration?

I have 2 situations:

situation 1 :  Vepa agents are installed on both BkHosts {A,B}. Configured in Cell manager gui as FC gateway with StoreOnce CoFC. in this scanerio , i start to backup VM and backup is succesful and transfer through FC gateway {BkHost-B} to StoreOnce CoFC. no traffic seen on ethernet ports.  - OK

It seems backup was done through BKHost-B FC gateway to COFC

 

Situation 2: i removed BKHosts-B FC gateway and run the same backup job. backup job started but i've seen the traffic flow on Ethernet ports from BKHosts-B {Send} to BKHost-A {Recv.}

Question is here , why traffic is flowing between BKHosts on Ethernet ports {10G} ? as per vepa agent configuration, it should select FC path to CoFC {Catalyst store}

one more question : I've also noticed that in SAN mode Backup Speed ....... 97.95 MB/s - It seems some issue with FC configuration or any other reason to have less bandwidth ? or just it is standard

Please have a look on below logs {situation-2}

[Normal] From: BSM@Cell_Manager "Vmware_Vcenter"  Time: 7/13/2016 10:26:37 AM
 Backup session 2016/07/13-4 started.

[Normal] From: BSM@Cell_Manager "Vmware_Vcenter"  Time: 7/13/2016 10:26:38 AM
 OB2BAR application on "BKHost-B" successfully started.

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:26:14 AM
 Resolving objects for backup on vCenter 'Vmware_Vcenter' ...

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:26:16 AM
 Add Virtual Machine to the backup ...
  Name: Virtual_Machine_Client
  Path: /SL/vm/Virtual_Machine_Client
  InstanceUUID: 503f9def-66ae-e0cf-0652-71853de18d00

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:26:19 AM
 Virtual Machine 'Virtual_Machine_Client': Locking vMotion ...

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:26:20 AM
 Creating folder /var/opt/omni/tmp/5d76139f-3ec6-48e6-8562-ccf785654aa3 ...

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:26:21 AM
 Virtual Machine 'Virtual_Machine_Client': Backing up configuration file Virtual_Machine_client.vmx ...

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:26:23 AM
 Virtual Machine 'Virtual_Machine_Client': Creating snapshot ...

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:26:29 AM
 Virtual Machine 'Virtual_Machine_Client': Getting Changed Blocks for disk scsi0:0.

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:29:49 AM
 Virtual Machine 'Virtual_Machine_Client' (UUID '503f9def-66ae-e0cf-0652-71853de18d00', Disk 'scsi0:0'): Starting full backup ...

[Normal] From: BMA@BKHost-A "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"  Time: 7/13/2016 10:30:21 AM
 STARTING Media Agent "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"

[Normal] From: BMA@BKHost-A "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"  Time: 7/13/2016 10:30:21 AM
 Loading medium from slot \\COFC-node1\FCS1/8c63f60a_5785ee07_576c_0019 to device StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]

[Normal] From: BMA@BKHost-A "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"  Time: 7/13/2016 10:30:21 AM
 Using interface path: \\COFC-node1\FCS1/8c63f60a_5785ee07_576c_0019

[Normal] From: OB2BAR_VEPA_BAR@BKHost-B "/SL"  Time: 7/13/2016 10:29:51 AM
 Starting OB2BAR Backup: Vmware_Vcenter:/4/Vmware_Vcenter%2F503f9def-66ae-e0cf-0652-71853de18d00%2F6000C297-c07e-f252-e38e-ad994ded8a38 "VEAgentDisk"

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:29:51 AM
 Virtual Machine 'Virtual_Machine_Client': Backing up ...
  Disk:                  scsi0:0
  Transport method:      SAN
  Disk buffer:           256 MB

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:29:51 AM
 Virtual Machine 'Virtual_Machine_Client': Disk 'scsi0:0' datastore information
  Datastore:             ESXi_Datastore.43.43
  Datastore type:        VMFS
  Datastore Storage WWN: 60002ac0000000000000002b0001a3b1

[Normal] From: BSM@Cell_Manager "Vmware_Vcenter"  Time: 7/13/2016 10:32:39 AM

 Server-side Deduplication Statistics for Vmware_Vcenter:/4/Vmware_Vcenter%2F503f9def-66ae-e0cf-0652-71853de18d00%2F6000C297-c07e-f252-e38e-ad994ded8a38 "VEAgentDisk".
 Using device: "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]@BKHost-A":
  Mbytes Total: .................     15017 MB
  Mbytes Written to Disk: .......        46 MB
  Deduplication Ratio: ..........     326.4 : 1

[Normal] From: OB2BAR_VEPA_BAR@BKHost-B "/SL"  Time: 7/13/2016 10:32:17 AM
 Backup Profile:

  Run Time ........... 0:02:26
  Backup Speed ....... 102.65 MB/s

[Normal] From: OB2BAR_VEPA_BAR@BKHost-B "/SL"  Time: 7/13/2016 10:32:17 AM
 Completed OB2BAR Backup: Vmware_Vcenter:/4/Vmware_Vcenter%2F503f9def-66ae-e0cf-0652-71853de18d00%2F6000C297-c07e-f252-e38e-ad994ded8a38 "VEAgentDisk"

[Normal] From: OB2BAR_VEPA_BAR@BKHost-B "/SL"  Time: 7/13/2016 10:32:22 AM
 Starting OB2BAR Backup: Vmware_Vcenter:/4/Vmware_Vcenter%2F503f9def-66ae-e0cf-0652-71853de18d00 "VEAgent"

[Normal] From: BMA@BKHost-A "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"  Time: 7/13/2016 10:32:55 AM
 Unloading medium to slot \\COFC-node1\FCS1/8c63f60a_5785ee07_576c_0019 from device StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]

[Normal] From: BMA@BKHost-A "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"  Time: 7/13/2016 10:32:55 AM
 Loading medium from slot \\COFC-node1\FCS1/8c63f60a_5785eea1_576c_001b to device StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]

[Normal] From: BMA@BKHost-A "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"  Time: 7/13/2016 10:32:56 AM
 Using interface path: \\COFC-node1\FCS1/8c63f60a_5785eea1_576c_001b

[Normal] From: BSM@Cell_Manager "Vmware_Vcenter"  Time: 7/13/2016 10:32:51 AM

 Server-side Deduplication Statistics for Vmware_Vcenter:/4/Vmware_Vcenter%2F503f9def-66ae-e0cf-0652-71853de18d00 "VEAgent".
 Using device: "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]@BKHost-A":
  Mbytes Total: .................         1 MB
  Mbytes Written to Disk: .......         1 MB
  Deduplication Ratio: ..........       1.0 : 1

[Normal] From: OB2BAR_VEPA_BAR@BKHost-B "/SL"  Time: 7/13/2016 10:32:28 AM
 Backup Profile:

  Run Time ........... 0:00:06
  Backup Speed ....... 0.00 MB/s

[Normal] From: OB2BAR_VEPA_BAR@BKHost-B "/SL"  Time: 7/13/2016 10:32:28 AM
 Completed OB2BAR Backup: Vmware_Vcenter:/4/Vmware_Vcenter%2F503f9def-66ae-e0cf-0652-71853de18d00 "VEAgent"

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:32:29 AM
 Virtual Machine 'Virtual_Machine_Client': Removing snapshot ...

[Normal] From: VEPALIB_VMWARE@BKHost-B ""  Time: 07/13/2016 10:32:33 AM
 Virtual Machine 'Virtual_Machine_Client': Unlocking vMotion ...

[Normal] From: BSM@Cell_Manager "Vmware_Vcenter"  Time: 7/13/2016 10:33:08 AM
 OB2BAR application on "BKHost-B" disconnected.

[Normal] From: BMA@BKHost-A "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"  Time: 7/13/2016 10:33:15 AM
 Unloading medium to slot \\COFC-node1\FCS1/8c63f60a_5785eea1_576c_001b from device StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]

[Normal] From: BMA@BKHost-A "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"  Time: 7/13/2016 10:33:15 AM
 COMPLETED Media Agent "StoreOnce_gw1_BKHost-A [GW 1488:0:15106138014348667170]"

[Normal] From: BSM@Cell_Manager "Vmware_Vcenter"  Time: 7/13/2016 10:33:09 AM

 Backup Statistics:
         
  Session Queuing Time (hours)         0.00       
  -------------------------------------------     
  Completed Disk Agents ........          2         
  Failed Disk Agents ...........          0         
  Aborted Disk Agents ..........          0         
  -------------------------------------------     
  Disk Agents Total  ...........          2         
  ===========================================     
  Completed Media Agents .......          1         
  Failed Media Agents ..........          0         
  Aborted Media Agents .........          0         
  -------------------------------------------     
  Media Agents Total  ..........          1         
  ===========================================     
  Throttled Gateways ...........          0         
  Gateways Total ...............          1         
  ===========================================     
  Overall Deduplication Ratio ..    319.5 : 1           
  ===========================================     
  Mbytes Total .................   15017 MB       
  Used Media Total .............          2         
  Disk Agent Errors Total ......          0   


============================================================================
                      Session completed successfully!
============================================================================

 

 

Many Thanks,

DPx

 

 

 

 

 

 

 