(DP) Support Tip: Copying from traditional media to StoreOnce

When data is copied from traditionl device (LTO, File  Library, Jukebox) to storeonce devices you might get error like: 

[Major] From: BMA@hostname  "Store_gw1 [GW 3192:0:6197155749911176774]" Time: 12/12/2015 12:22:18 PM
[90:51] \\hostname\Store\038da8c0_566e980a_07d8_004a
Cannot write to device (JSONizer error: Invalid inputs)

To avoid this copy specification should be configured so that it can start as many BMA processes for target gateway selected, as the concurrency setting used in the backup eg: 

1. if original backup concisted ot 10 objects multiplexed to single LTO drive (using concurrency 10)

2. copy specification should be configured with load balancing of at least 1-10. So that one BMA can be started for each multiplexed object

If this condition is not met, multiple RMAs will send data to single BMA leading to above mentioned error